PhEx equipment
Electrical Capacitance Tomography System
Non-destructive ECT instrumentation for real-time 2D and 3D imaging of multiphase material distribution in pipes and vessels.
Product Description
Working Principle
Electrical capacitance tomography uses capacitance sensors and reconstruction algorithms to image multiphase material distribution inside pipes or vessels in real time.
Product Advantages / Key Features
● Non-Destructive Testing
ECT is a non-invasive, radiation-free inspection technology that does not affect the physical and chemical properties of the inspected material.
● Real-Time Imaging
With high imaging speed, it enables real-time monitoring and is suitable for rapidly changing scenarios in industrial process monitoring.
● 2D and 3D Imaging
Supports both 2D and 3D imaging, providing more comprehensive information on material distribution, making it particularly suitable for the precise monitoring of complex multiphase flows.
● High Sensitivity
Sensitive to distribution changes in non-conductive materials, such as solids, liquids, and gases, enabling precise detection of multiphase flow distribution.
● Flexible Data Processing
Advanced reconstruction algorithms and image processing technologies enable high-precision image reconstruction, with resolution and processing speed adjustable to meet specific requirements.
● Low cost
Compared to other tomographic imaging technologies, ECT equipment has lower manufacturing costs and is simpler to maintain and operate.
● Simple structure
Capacitive sensors feature a simple structure with no moving parts, offering a long service life and high durability. 58
Technical Applications
● Drug Dissolution Profiling
Real-time characterization of AP concentration using custom dissolution cells.
● Fluidized Bed Process Characterization
Real-time dynamic monitoring of moisture content, gas-solid phase distribution, and flow patterns during drying, granulation, and coating processes to provide process guidance and control for fluidized bed operations.
● Mixing Process Characterization
Applied to two-dimensional and three-dimensional monitoring of mixing processes to ensure uniformity and consistency in drug manufacturing.
● Hot-Melt Granulation Process Characterization
Utilizes 2D and 3D imaging technologies to assess mixing and distribution during the hot-melt granulation process, thereby optimizing production.
● Characterization of Traditional Chinese Medicine Extraction Processes
By correlating real-time dynamics with ECT based on changes in active ingredients and concentrations during the extraction process, the composition and concentration of the extract can be characterized, providing better guidance for determining the endpoint and optimizing the production process. 60
Product Specifications
NO. Item Parameters Remarks
1 Model PH-ECT 01
Single-layer measurement, dual-layer
2 Measurement Mode
measurement
3 Number of Electrodes 8、12、24
Imaging Frame Rate Depends on measurement mode and number
4 200-700
(Frames/Second) of measurement electrodes
Measurement Frequency
5 200
(kHz)
±1 0 -2 pF measurement range
Measurement accuracy
(fF)
±10 100 fF -20 pF measurement range
Capacitance resolution
7 0.1
(fF)
8 Spatial resolution (mm) 0.1-5.0
Ambient Temperature (
9 -20 - 60
°C)
Dielectric temperature (
10 0-125 Customizable for special applications
°C)
100-240V,50/60Hz AC
11 Supply voltage
18-36V DC
12 Communication Interface USB-B Male connector
Cross-sectional imaging using a single- Suitable for detecting material distribution
13 2D imaging
layer electrode array inside pipes and vessels
Multi-layer electrode arrays enable 3D Suitable for multiphase flow and structural
14 3D imaging
imaging inspection inside complex vessels